Vents
Energy-saving axial-flow extractor fan for walls & ceilings Arc Smart Black ND 100 mm
nominal size: 100 mm
wattage: 2.7 W
max. airflow: 115 m³/h
IP44 protection against splashing water
timer, air quality, motion sensor, humidity sensor, light sensor
Item number Arc-SmartSW
immediately ready for dispatch, delivery time 2 - 3 days
* Incl. VAT excl. Shipping
Dimensions and technical details
- 100-240 V ~ 50/60 Hz
- Housing colour: black
- Housing material: UV-resistant ABS
- Nominal diameter: 100 mm
- Bearing: ball bearing
- Speed levels: 5
- Wattage: 0.4 / 0.6 / 0.8 / 1.6 / 2.7 W
- Current consumption: 0.018 / 0.019 / 0.021 / 0.029 / 0.038 A
- Airflow rate: 20 / 40 / 60 / 90 / 115 m³/h
- Sound pressure level Lp-3m: 9 / 13 / 18 / 22 / 27 dB(A)
- IP rating: IP44
- Diameter housing: 193 mm
- Diameter duct connection: 100 mm
- Depth: 55 mm
- Total depth: 81 mm
- Weight: 0.5 kg
- Thermal overload protection
- Mounting options: wall, ceiling
- Application: direct connection to the ventilation shaft
- Smart home control via Vents Home app (Apple App Store, Google Play Store)
- Operating mode Standby: The fan is activated by a signal from a sensor.
- Operating mode 24 Hours: The fan runs at a low ventilation level for 24 hours. When the sensor signal is received, the fan switches to the ventilation level: speed 1 / 2 / 3.
- Operating mode Do Not Disturb: Adjustable time interval in which the fan does not react to sensor signals or switch activation. Only possible in combination with 24 Hours mode.
- Operating mode Interval: Automatic interval ventilation every 12 hours for 30 minutes with the set ventilation level speed 1 / 2 / 3.
- Operating mode Max Boost: The fan runs at maximum speed.
- Operating mode Humidity Sensor Manual: Adjustable setpoint in the range 40% - 80% RH. If the setpoint is exceeded, the fan switches to the preset speed 3 / 4 / 5.
- Operating mode Humidity Sensor Automatic: The fan independently selects the optimal humidity setpoint for the room.
- Operating mode Motion Sensor: Switch-on delay 30 seconds. When triggered, the fan switches to the preset speed 2 / 3 / 4 / 5. As soon as no movement is detected and the countdown of the timer switch has expired, the fan switches to the previous operation.
- Operating mode Light Sensor: Switch-on delay 30 seconds. When triggered, the fan switches to the selected speed 2 / 3 / 4 / 5. If the sensor detects that the light intensity is not sufficient, the fan switches to the previous operation after the timer switch has expired.
- Operating mode Air Quality Sensor Manual: Adjustable setpoint in the range of the sensitivity level. If the setpoint is exceeded, the fan switches to the selected speed 3 / 4 / 5.
- Operating mode Air Quality Sensor Automatic: The fan automatically determines the optimal setpoint for the air quality sensor and only reacts to sudden changes in the air quality in the room.
- Operating mode Timer: Switch-on delay 30 seconds, timer switch extends fan operation by 0, 15 or 30 minutes after sensor or Boost activation.